Minimum Concrete Cover Requirements. Specific RC Members. Code Provisions

Sun 11th Jun 2023 by ilyas

Minimum concrete cover requirements are presented below for various building codes.


Japanese Building Code

The Japanese building code provides the following guidance:

Type of StructureDesign Cover (mm)
Not in Contact with SoilSlabInternal30
External40
Column / Beam / Structural WallInternal40
External50
Non-Structural WallInternal30
External40
Ground Floor Slab 50
In Contact with SoilColumn / Beam / Structural Walls / Slabs50
Foundation Slabs70
Foundations70

These values include a 10 mm allowance on the nominal cover to account for construction tolerance.


ACI 318

The American Concrete Institute (ACI 318-11) provides the following recommendations for minimum cover:

Type of StructureDesign Cover (mm)
Permanently in Contact with the Ground75
In Contact with Ground or WaterNo. 16 rebar and smaller40
No. 19 to No. 57 rebar50
Not Exposed to Weather or in Contact with the GroundSlabs, Walls, JoistsNo. 36 rebar and smaller20
No. 43 and No. 47 rebar40
Beams, ColumnsAll rebar40
Shells, Folded Plate MembersNo. 16 rebar and smaller13
No. 19 rebar and larger20

For other conditions, such as corrosive environments or a minimum specified fire resistance, refer to the relevant clauses in the ACI code.